Post written by Jahnvi Dhar, MD, DM, from the Department of Gastroenterology and Hepatology, Punjab Institute of Liver and Biliary Sciences, Mohali, and Jayanta Samanta, MBBS, MD, DM, from the Department of Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.

This study systematically compares 2 EUS-guided coil and glue embolization strategies for gastric varices (GVs), targeting the feeder vessel (EUS-guided feeder vessel obliteration [EUS-F]) versus the conventional submucosal variceal component (SVC). In 135 patients with GVs and a discernible feeder vessel on EUS, we analyzed reintervention rates (primary outcome), along with volume of cyanoacrylate glue, number of coils required, variceal obliteration rates, and bleeding events (secondary outcomes) at 6 months across both strategies.

Esophageal varices account for the majority of portal hypertension-related bleeding, whereas GVs are noted only in 10% to 30% of these cases. Although GVs bleed infrequently, they are usually catastrophic, leading to higher transfusion requirements, recurrent bleeding, and mortality. Hence, the management of bleeding GVs can be challenging and warrants the need for better strategies to prevent recurrent bleeding and reintervention rates. The dynamics of bleeding GVs is different from that of esophageal varices, wherein portal pressure dictates the pathophysiology.
In the case of GVs, size of the varix (submucosal component) and associated perforator/feeder vessels govern the bleeding rates, which cannot be properly assessed on standard endoscopy, unlike EUS. The conventional strategy using EUS is to target the SVC of the GV. The feeder or perforator vessels that “feed” the SVC can be localized and targeted on EUS.
We hypothesized that targeting the feeder vessel over the conventional SVC may decrease the need for coil and glue required for GV obliteration as well as lead to higher rates of obliteration on follow-up, thus minimizing the recurrent bleeding and reintervention rates. Yet, this targeted feeder approach (EUS-F) had never been systematically compared head-to-head with the conventional EUS-guided SVC strategy, to our knowledge, leaving a critical evidence gap that this study directly addresses.
Among 135 GV patients analyzed (EUS-F 32; EUS-guided SVC 103), we found that the strategy of EUS-F showed lower requirements of both coil (P = .0001) and glue (P = .0001), not only at the index procedure, but also overall requirement of coils (1.94 ± 0.91 vs 2.79 ± 1.76; P = .001) and glue (1.88 ± 0.64 vs 2.83 ± 1.70 mL; P < .0001) at 6 months. Overall reintervention rates at 6 months were significantly lower in the EUS-F arm (3.1% vs 17.5%; P = .04), along with the number of EUS sessions needed for complete GV obliteration (P = .02), without an increase in adverse events.
These findings establish feeder vessel targeting as a more efficient and durable obliteration strategy when it is identifiable on EUS. To our knowledge, this is the first head-to-head comparison of these 2 strategies, adding concrete evidence to rationalize the feeder-first approach. Future research should focus on multicenter prospective or randomized trials with cost-efficacy analysis, which will help substantiate the results of our study, possibly helping the feeder vessel approach with becoming the first-line strategy in these subsets of patients.
To our knowledge, this is the first systematic comparison of feeder vessel versus SVC targeting in EUS-guided angioembolization of GVs using coil-glue combination. It showed that targeting the feeder vessel, when feasible and discernible, over the SVC (conventional method) results in significantly lower requirements of coil and glue, with significantly lower reintervention rates, which might translate to a more cost-effective strategy. The accompanying videos illustrate the step-by-step technique and may serve as a practical reference for endoscopists adopting this approach. We hope these findings catalyze a paradigm shift toward feeder-first obliteration whenever EUS Doppler permits clear delineation of the feeder vessel.

EUS-guided management of Arakawa type II varix: (A) 2 distinct feeder vessels noted (green outline and yellow outline) supplying the submucosal component (orange outline); (B) the first set of feeder targeted and punctured with a 19-gauge needle; (C) obliteration of the first set of feeder; (D) targeting the second set of feeder (green outline: obliterated the first feeder; orange outline: submucosal variceal component); (E) coils being deployed within the second feeder set; (F) complete obliteration of the 2 feeders and the submucosal component.
Read the full article online.
The information presented in Endoscopedia reflects the opinions of the authors and does not represent the position of the American Society for Gastrointestinal Endoscopy (ASGE). ASGE expressly disclaims any warranties or guarantees, expressed or implied, and is not liable for damages of any kind in connection with the material, information, or procedures set forth.